Removed Pin From Net: NetName=GND Pin=C20-1 Removed Pin From Net: NetName=5V_VBUS Pin=C20-2 Removed Pin From Net: NetName=24VDC_1 Pin=J5-1 Removed Pin From Net: NetName=DI_NPN_1 Pin=J5-2 Removed Pin From Net: NetName=DI_NPN_12 Pin=J6-1 Removed Pin From Net: NetName=DI_NPN_13 Pin=J6-2 Removed Pin From Net: NetName=DI_NPN_2 Pin=J8-1 Removed Pin From Net: NetName=DI_NPN_3 Pin=J8-2 Removed Pin From Net: NetName=Rx_Jig Pin=J9-1 Removed Pin From Net: NetName=Tx_Jig Pin=J10-1 Removed Pin From Net: NetName=DI_NPN_14 Pin=J11-1 Removed Pin From Net: NetName=DI_NPN_15 Pin=J11-2 Removed Pin From Net: NetName=DI_NPN_4 Pin=J13-1 Removed Pin From Net: NetName=DI_NPN_5 Pin=J13-2 Removed Pin From Net: NetName=DI_NPN_16 Pin=J16-1 Removed Pin From Net: NetName=DI_NPN_17 Pin=J16-2 Removed Pin From Net: NetName=DI_NPN_6 Pin=J18-1 Removed Pin From Net: NetName=DI_NPN_7 Pin=J18-2 Removed Pin From Net: NetName=DI_NPN_8 Pin=J21-1 Removed Pin From Net: NetName=DI_NPN_9 Pin=J21-2 Removed Pin From Net: NetName=DI_NPN_10 Pin=J32-1 Removed Pin From Net: NetName=DI_NPN_11 Pin=J32-2 Removed Pin From Net: NetName=WDI_MCU Pin=R11-1 Removed Pin From Net: NetName=GND Pin=R11-2 Removed Pin From Net: NetName=MCU_RST Pin=R16-1 Removed Pin From Net: NetName=24VDC_1 Pin=R63-2 Removed Pin From Net: NetName=24VDC_1 Pin=R64-2 Removed Pin From Net: NetName=24VDC_1 Pin=R65-2 Removed Pin From Net: NetName=24VDC_1 Pin=R66-2 Removed Pin From Net: NetName=24VDC_1 Pin=R67-2 Removed Pin From Net: NetName=24VDC_1 Pin=R68-2 Removed Pin From Net: NetName=24VDC_1 Pin=R73-2 Removed Pin From Net: NetName=24VDC_1 Pin=R74-2 Removed Pin From Net: NetName=24VDC_1 Pin=R75-2 Removed Pin From Net: NetName=24VDC_1 Pin=R76-2 Removed Pin From Net: NetName=GND Pin=U3-2 Removed Pin From Net: NetName=WDI_MCU Pin=U3-4 Removed Pin From Net: NetName=5V_VBUS Pin=U3-5 Removed Pin From Net: NetName=RS485-2-RX Pin=U4-14 Removed Pin From Net: NetName=RS485-2-DE Pin=U4-15 Removed Pin From Net: NetName=RS485-2-TX Pin=U4-16 Removed Pin From Net: NetName=DI4 Pin=U4-17 Removed Pin From Net: NetName=DI5 Pin=U4-18 Removed Pin From Net: NetName=DI6 Pin=U4-19 Removed Pin From Net: NetName=DI8 Pin=U4-20 Removed Pin From Net: NetName=DI9 Pin=U4-21 Removed Pin From Net: NetName=DI10 Pin=U4-22 Removed Pin From Net: NetName=DI11 Pin=U4-23 Removed Pin From Net: NetName=DI12 Pin=U4-24 Removed Pin From Net: NetName=Bit5 Pin=U4-36 Removed Pin From Net: NetName=Bit4 Pin=U4-37 Removed Pin From Net: NetName=Bit3 Pin=U4-39 Removed Pin From Net: NetName=DO_NO_1 Pin=U15-1 Removed Pin From Net: NetName=DO_COM_1 Pin=U26-3 Removed Pin From Net: NetName=DO_COM_1 Pin=U26-4 Removed Pin From Net: NetName=DO_NO_1 Pin=U28-1 Change Component Designator: OldDesignator=J9 NewDesignator=J? Change Component Designator: OldDesignator=J10 NewDesignator=J? Added Component: Designator=J17(2P-5.08) Add component (AddParameter): Name = "Category"; Value = "Connector"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Detailed Value"; Value = "2P-5.08"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Link sale"; Value = "#https://www.digikey.com/en/products/detail/te-connectivity-amp-connectors/282837-2/2187973#"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Manufacture"; Value = "TE Connectivity AMP Connectors"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Mounting type"; Value = "TH"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Partnumber"; Value = "282837-2"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Supplier"; Value = "Digikey"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Value"; Value = "2P-5.08"; VariantName = "[No Variations]" Added Component: Designator=J?(JUMP-2.54-3PIN-M-TH-CLOSED) Add component (AddParameter): Name = "Category"; Value = "Connector"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Creator"; Value = "Tunn"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Detailed Value"; Value = "3P2.54"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Manufacture"; Value = "MINH HÀ"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Mounting type"; Value = "TH"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Partnumber"; Value = "JUMP-2.54-3PIN-M-TH-CLOSED"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Supplier"; Value = "MINH HÀ"; VariantName = "[No Variations]" Add component (AddParameter): Name = "Value"; Value = "3P2.54"; VariantName = "[No Variations]" Added Pin To Net: NetName=MCU_RST Pin=J?-1 Added Pin To Net: NetName=Rx_Jig Pin=J?-1 Added Pin To Net: NetName=Tx_Jig Pin=J?-1 Added Pin To Net: NetName=MD Pin=J?-2 Added Pin To Net: NetName=GND Pin=J?-3 Added Pin To Net: NetName=5V_MCU Pin=U2-10 Added Pin To Net: NetName=DI4 Pin=U4-14 Added Pin To Net: NetName=DI5 Pin=U4-15 Added Pin To Net: NetName=DI6 Pin=U4-16 Added Pin To Net: NetName=DI8 Pin=U4-17 Added Pin To Net: NetName=DI9 Pin=U4-18 Added Pin To Net: NetName=DI10 Pin=U4-19 Added Pin To Net: NetName=DI11 Pin=U4-20 Added Pin To Net: NetName=DI12 Pin=U4-21 Added Pin To Net: NetName=RS485-2-DE Pin=U4-36 Added Pin To Net: NetName=RS485-2-TX Pin=U4-37 Added Pin To Net: NetName=RS485-2-RX Pin=U4-39 Change Net Name : Old Net Name=24VDC_1 New Net Name=24VDC_3 Add Net: Net with name "24VDC_3" already exists Add Net: Net with name "DI_NPN_1" already exists Add Net: Net with name "DI_NPN_2" already exists Add Net: Net with name "DI_NPN_3" already exists Add Net: Net with name "DI_NPN_4" already exists Add Net: Net with name "DI_NPN_5" already exists Add Net: Net with name "DI_NPN_6" already exists Add Net: Net with name "DI_NPN_7" already exists Add Net: Net with name "DI_NPN_8" already exists Add Net: Net with name "DI_NPN_9" already exists Add Net: Net with name "DI_NPN_10" already exists Add Net: Net with name "DI_NPN_12" already exists Add Net: Net with name "DI_NPN_14" already exists Add Net: Net with name "DI_NPN_16" already exists Add Net: Net with name "DO_COM_1" already exists Add Net: Net with name "DO_NO_1" already exists Added Pin To Net: NetName=NetU15_1 Pin=U15-1 Added Net: Name=NetU15_1 Change Class Name : Old Net Name=Room Definition4 New Net Name=DO1-5 Added Class: Name=DO6-10 Added Class: Name=DO11-15 Added Class: Name=MCU Added Class: Name=Power Added Member To Class: ClassName=DO1-5 Member=Component C23 0.1uF Added Member To Class: ClassName=DO1-5 Member=Component C24 0.1uF Added Member To Class: ClassName=DO1-5 Member=Component C32 0.1uF Added Member To Class: ClassName=DO1-5 Member=Component C56 0.1uF Added Member To Class: ClassName=DO1-5 Member=Component D4 6.2V Added Member To Class: ClassName=DO1-5 Member=Component D5 6.2V Added Member To Class: ClassName=DO1-5 Member=Component D6 6.2V Added Member To Class: ClassName=DO1-5 Member=Component D10 6.2V Added Member To Class: ClassName=DI2 Member=Component J17 2P-5.08 Added Member To Class: ClassName=DO1-5 Member=Component J23 2P-5.08 Added Member To Class: ClassName=DO1-5 Member=Component J24 TP Added Member To Class: ClassName=DO1-5 Member=Component J25 TP Added Member To Class: ClassName=DO1-5 Member=Component J26 2P-5.08 Added Member To Class: ClassName=DO1-5 Member=Component J27 TP Added Member To Class: ClassName=DO1-5 Member=Component J28 TP Added Member To Class: ClassName=DO1-5 Member=Component J29 2P-5.08 Added Member To Class: ClassName=DO1-5 Member=Component J30 TP Added Member To Class: ClassName=DO1-5 Member=Component J31 TP Added Member To Class: ClassName=DO1-5 Member=Component Q1 40V-0.2A Added Member To Class: ClassName=DO1-5 Member=Component Q2 40V-0.2A Added Member To Class: ClassName=DO1-5 Member=Component Q3 40V-0.2A Added Member To Class: ClassName=DO1-5 Member=Component Q5 40V-0.2A Added Member To Class: ClassName=RS485 Member=Component R41 1M Added Member To Class: ClassName=RS485 Member=Component R44 10R Added Member To Class: ClassName=RS485 Member=Component R46 1M Added Member To Class: ClassName=DO1-5 Member=Component R77 1K Added Member To Class: ClassName=DO1-5 Member=Component R78 1K Added Member To Class: ClassName=DO1-5 Member=Component R79 10K Added Member To Class: ClassName=DO1-5 Member=Component R80 10K Added Member To Class: ClassName=DO1-5 Member=Component R81 1K Added Member To Class: ClassName=DO1-5 Member=Component R83 10K Added Member To Class: ClassName=DO1-5 Member=Component R85 1K Added Member To Class: ClassName=DO1-5 Member=Component R86 10K Added Member To Class: ClassName=DO1-5 Member=Component U15 Relay 5V-8P Added Member To Class: ClassName=DO1-5 Member=Component U16 Relay 5V-8P Added Member To Class: ClassName=DO1-5 Member=Component U17 Relay 5V-8P Added Member To Class: ClassName=DO1-5 Member=Component U19 Relay 5V-8P Change Room Name: Old Name=RoomDefinition_2 New Name=RS485 Change Room Scope: Old Scope=InComponentClass('Room Definition5') New Scope=InComponentClass('RS485') Change Room Name: Old Name=RoomDefinition New Name=DO11-15 Change Room Scope: Old Scope=InComponentClass('Room Definition6') New Scope=InComponentClass('DO11-15') Added Room: Name=DI2 Added Room: Name=DI Added Room: Name=Power